Eco-friendly non-combustible paint

GRAE COAT ANTA

Product Overview

– Non-flammable agent that reacts to initial ignition at about 200℃ with special acrylic emulsion resin
– Incombustible materials expand 70 to hundreds of times during initial ignition to protect buildings and structures from fire
– State-of-the-art eco-friendly water-based non-combustible paint

Product Features

At initial ignition above  200℃, self-extinguishing expands hundreds of times
Protect against fire by delaying fire from flames to buildings, structures, and devices
Excellent weather resistance and adhesion, so it can be painted even on metal products.
It can prevent condensation that may occur due to the heat insulation effect with the outside, thus suppressing mold
Easy to construct with water-based eco-friendly products

Physical properties

Test result

Test ItemsunitSample classificationResultTest Methods
Semi-incombustible test-total radiated heat (THR600)---Ministry of Land, Infrastructure and Transport notice No. 2018-771 (2018)
-N0.1MJ/m²-0.7
-N0.2MJ/m²-0.2
-N0.3MJ/m²-1.2
Semi-incombustible test-200kW/m2 exceeding time---Ministry of Land, Infrastructure and Transport notice No. 2018-771 (2018)
-N0.1s-0
-N0.2s-0
-N0.3s-0
Semi-incombustible test-Test specimen after test ---Ministry of Land, Infrastructure and Transport notice No. 2018-771 (2018)
-N0.1--clear
-N0.2--clear
-N0.3--clear
Semi-incombustible test-Gas hazard test Ministry of Land, Infrastructure and Transport notice No. 2018-771 (2018)
-N0.1min:s-10 : 22
-N0.2min:s-13 : 32
CategoryContentsItemContents
Chief ingredient Porous ceramic,
highly elastic acrylic emulsion
Theoretical coating thickness1.2m²/L
TypeHydrophilicshapeOne component
Solid Content65%Dry film thickness0.5mm or more
Important0.85colorgrey
PH7.5~8.0Painting appearanceMatte

Construction method

Removes laitance, oil and  other contaminants from the bottom surface, and fills grooves and cracks with elastic putty or quick tie
Apply Graanta evenly with brush, roller, spray, etc.
The repainting interval should be applied after confirming that it has been dried after 5 hours at room temperature, and applied at least 3 times.
When dilution, the water should be within 5% and sufficiently stirred for at least 5 minutes using a low speed stirrer.

Site

Blend

Application

Precautions

Avoid direct sunlight during work and refrain from  painting at temperatures below 5℃ and above 35℃ and above 80% humidity.
Please refrain from mixing with other products and Please refrain from mixing excessive water.
Store in a shady place above 5℃ and below 30℃ (do not freeze or freeze)

Construction site utility

Building exterior

Inside the building

Boiler room

Rooftop

Roof

Steel structure

Economics of a product

categoryNon-combustible materialSemi-incombustible materialFlame retardant material
DefinitionArticle 2 (non-combustible materials), standards for flame retardant performance and fire spread prevention structure of building finishing materialsArticle 3 (Semi-Non-combustible Materials) Standards for Flame Retardant Performance and Fire Spread Prevention Structure of Building Finishing MaterialsArticle 4 (Flame Retardant Materials) Standards for Flame Retardant Performance and Fire Spread Prevention Structure of Building Finishing Materials
Test nameKS F ISO 1182 (Test method for nonflammability of building materials)KS F ISO 5660-1 [Combustion performance test-Heat emission, smoke generation, mass reduction rate-Part 1: Heat emission rate (concalorimeter method)]KS F ISO 5660-1 [Combustion performance test-Heat emission, smoke generation, mass reduction rate-Part 1: Heat emission rate (concalorimeter method)]
Performance criteriaThe maximum temperature in the furnace for 20 minutes after the start of the heating test should not rise above the final equilibrium temperature by 20K (however, if the equilibrium is not reached for 20 minutes, the average temperature for the final 1 minute shall be the final equilibrium temperature). The mass reduction rate of is less than 30%.The total heat dissipation rate for 10 minutes after the start of the heating test is 8MJ/㎡ or less, and the maximum heat release rate for 10 minutes does not exceed 200kW/㎡ continuously for 10 seconds or more, and fires that penetrate the test body after heating for 10 minutes. There should be no melting (in the case of composite materials, including all melting and extinguishing of the core material), etc.The total heat emission for 5 minutes after the start of the heating test is 8 MJ/㎡ or less, and the maximum heat release rate for 5 minutes does not exceed 200 kW/㎡ continuously for 10 seconds or more, and the test body after heating for 5 minutes (including core material in case of composite material) There should be no cracks, holes and melting through the hole.
Corresponding materialConcrete, stone, brick, steel, glass, aluminum, glass wool, ash (more than 24mm thick), cement board, fiber cement board, gypsum cement board, extruded cement boardGypsum board, wooden cement board, pulp cement board, mineral texFlame retardant plate, flame retardant plastic plate

Economics of a product

CategoryGraecoat antaInsulation paint from other companiesRemark
IngredientSpecial acrylic emulsion Special inorganic ceramic coating agent
Characteristic At initial ignition above 200℃, self-extinguishing expands hundreds of times . Protect against fire by delaying fire from flames to buildings, structures, and devices . Excellent weather resistance and adhesion, so it can be painted even on metal products. It can prevent condensation that may occur due to the heat insulation effect with the outside, thus suppressing mold. Easy to construct with water-based eco-friendly products.Protect against fire by delaying fire from flames to buildings, structures, and devices. Excellent weather resistance and adhesion, so it can be painted even on metal products. Prevents condensation that may occur due to the insulation effect with the outside.
DifferencePaint using our patented technology Article 3 Standards for Flame Retardant Performance and Fire Spread Prevention Structure of Building Finishing Materials (Semi-incombustible material)Paints using foreign imported paints or technologies with poor performance Article 3 Standards for Flame Retardant Performance and Fire Spread Prevention Structure of Building Finishing Materials (Semi-incombustible material)